Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Clin Res Cardiol ; 112(5): 594-604, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36507943

RESUMO

AIMS: Sleep-disordered breathing (SDB) and its subtype central sleep apnoea (CSA) are highly prevalent in patients with heart failure and associated with worse prognosis. Whereas pharmacological therapy of heart failure has been shown to ameliorate CSA, results from previous studies on the effect of mitral regurgitation therapy on SDB are contradicting. The aim of this study was to assess the impact of transcatheter edge-to-edge mitral valve repair (TEER) on prevalence and severity of CSA. METHODS AND RESULTS: We enrolled 47 patients undergoing TEER for symptomatic mitral regurgitation in a prospective study. Secondary mitral regurgitation and left ventricular ejection fraction < 50% were present in 79% and 68% of patients, respectively. Respiratory polygraphy was performed before TEER in a compensated condition and four weeks after the procedure. 34 patients completed the follow-up. At baseline, 19 (56%) patients showed moderate-to-severe SDB, of whom 13 (68%) were classified as CSA. Both apnoea-hypopnoea index and percentage of recorded time spent in Cheyne-Stokes respiration strongly decreased from baseline to follow-up (median [IQR] 16 [7-30] vs. 7 [4-15] /h, p = 0.007; 6 [0-34] vs. 0 [0-8] %, p = 0.008). Median relative reduction of central apnoea index was 75% (p = 0.023), while obstructive apnoea index did not change significantly. Increase in stroke volume after TEER and high systolic pulmonary artery pressure at baseline predicted a > 50% reduction of both Apnoea-hypopnoea index and Cheyne-Stokes respiration. CONCLUSION: TEER is associated with a significant short-term reduction of CSA and Cheyne-Stokes respiration in high-risk patients, strengthening its value as an effective treatment option for advanced heart failure.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Síndromes da Apneia do Sono , Apneia do Sono Tipo Central , Humanos , Respiração de Cheyne-Stokes/terapia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Valva Mitral/cirurgia , Estudos Prospectivos , Função Ventricular Esquerda , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Resultado do Tratamento
2.
Basic Res Cardiol ; 117(1): 45, 2022 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-36068416

RESUMO

Tachycardiomyopathy is characterised by reversible left ventricular dysfunction, provoked by rapid ventricular rate. While the knowledge of mitochondria advanced in most cardiomyopathies, mitochondrial functions await elucidation in tachycardiomyopathy. Pacemakers were implanted in 61 rabbits. Tachypacing was performed with 330 bpm for 10 days (n = 11, early left ventricular dysfunction) or with up to 380 bpm over 30 days (n = 24, tachycardiomyopathy, TCM). In n = 26, pacemakers remained inactive (SHAM). Left ventricular tissue was subjected to respirometry, metabolomics and acetylomics. Results were assessed for translational relevance using a human-based model: induced pluripotent stem cell derived cardiomyocytes underwent field stimulation for 7 days (TACH-iPSC-CM). TCM animals showed systolic dysfunction compared to SHAM (fractional shortening 37.8 ± 1.0% vs. 21.9 ± 1.2%, SHAM vs. TCM, p < 0.0001). Histology revealed cardiomyocyte hypertrophy (cross-sectional area 393.2 ± 14.5 µm2 vs. 538.9 ± 23.8 µm2, p < 0.001) without fibrosis. Mitochondria were shifted to the intercalated discs and enlarged. Mitochondrial membrane potential remained stable in TCM. The metabolite profiles of ELVD and TCM were characterised by profound depletion of tricarboxylic acid cycle intermediates. Redox balance was shifted towards a more oxidised state (ratio of reduced to oxidised nicotinamide adenine dinucleotide 10.5 ± 2.1 vs. 4.0 ± 0.8, p < 0.01). The mitochondrial acetylome remained largely unchanged. Neither TCM nor TACH-iPSC-CM showed relevantly increased levels of reactive oxygen species. Oxidative phosphorylation capacity of TCM decreased modestly in skinned fibres (168.9 ± 11.2 vs. 124.6 ± 11.45 pmol·O2·s-1·mg-1 tissue, p < 0.05), but it did not in isolated mitochondria. The pattern of mitochondrial dysfunctions detected in two models of tachycardiomyopathy diverges from previously published characteristic signs of other heart failure aetiologies.


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Animais , Cardiomiopatias/etiologia , Humanos , Mitocôndrias/metabolismo , Miocárdio/metabolismo , Coelhos
3.
Vaccines (Basel) ; 10(4)2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35455346

RESUMO

Vaccine-induced immune thrombotic thrombocytopenia (VITT) with venous thrombosis is a rare complication of SARS-CoV-2 vaccination with ChAdOx1 (AstraZeneca) and AD26.COV2.S (Johnson & Johnson, New Brunswick, NJ, USA) associated with high mortality. At present, there are no known differences in the pathophysiology or risk factors of VITT with the AstraZeneca vaccine (ChAdOx1) compared with the Johnson & Johnson vaccine (AD26.COV2.S). Herein, we present the case of a healthy 39-year-old patient with VITT after having received the vaccine Ad26.COV2.S. Ten days after vaccination, the patient developed a deep vein thrombosis and subsequent pulmonary embolism. A computed tomography scan of the abdomen showed adrenal gland bleeding and an adrenocorticotrophic hormone stimulation test diagnosed adrenal insufficiency. Therapy with intravenous immunoglobulin, argatroban and hydrocortisone was initiated immediately after diagnosis. The patient left the hospital 22 days after admission with the diagnosis of adrenal insufficiency but otherwise in good health. To the best of our knowledge, five cases of VITT and adrenal bleeding have been described to date in the literature but the presented case was the first to occur after immunisation with the vaccine of Johnson & Johnson. In summary, VITT-associated adrenal dysfunction is a very rare complication of vaccination with an adenoviral vector-based COVID-19 vaccine.

4.
Catheter Cardiovasc Interv ; 99(4): 1259-1267, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35084083

RESUMO

BACKGROUND: Transcatheter mitral valve repair is an increasingly used therapy for mitral regurgitation which requires fluoroscopic guidance. Limiting radiation exposure during lengthy procedures is important for both patient and operator safety. This study aimed to investigate radiation dose during contemporary use of MitraClip implantation and the effects of a dose reduction program. METHODS: A total of 115 patients who underwent MitraClip implantation were prospectively enrolled in a single-center observational study. During the inclusion period, our institution adopted a radiation dose reduction program, comprising lowering of fluoroscopy pulse rate and image target dose. The first 58 patients were treated with conventional fluoroscopy settings, while the following 57 patients underwent the procedure with the newly implemented low dose protocol. RESULTS: Radiation dose area product significantly decreased after introduction of the low dose protocol (693 [366-1231] vs. 2265 [1517-3914] cGy·cm2 , p < 0.001). After correcting for fluoroscopy time, gender and body mass index, the low dose protocol emerged as a strong negative predictor of radiation dose (p < 0.001), reducing dose area product by 64% (95% confidence interval [57-70]). Device time, device success, and procedural safety did not differ between the normal dose and low dose group. Furthermore, the low dose protocol was not associated with an increased incidence of a combined endpoint consisting of death, repeat intervention, or heart surgery during 12 months follow-up. CONCLUSION: Reduction of radiation exposure during transcatheter mitral valve repair by 64% is feasible without affecting procedural success or safety.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Exposição à Radiação , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Resultado do Tratamento
5.
PLoS One ; 15(5): e0232817, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32463820

RESUMO

BACKGROUND AND OBJECTIVES: MitraClip implantation is an established therapy for secondary mitral regurgitation (MR) in high-risk patients and has shown to improve several important outcome parameters such as functional capacity. Patient selection is both challenging and crucial for achieving therapeutic success. This study investigated baseline predictors of functional improvement as it was quantified by the six-minute walk distance (6MWD) after transcatheter mitral valve repair. METHODS AND RESULTS: We retrospectively analyzed 79 patients with secondary MR treated with MitraClip implantation at an academic tertiary care center. Before and four weeks after the procedure, all patients underwent comprehensive clinical assessment, six-minute walk tests and echocardiography. 6MWD significantly improved after MitraClip therapy (295 m vs. 265 m, p < 0.001). A linear regression model including seven clinical baseline variables significantly predicted the change in 6MWD (p = 0.002, R2 = 0.387). Female gender, diabetes mellitus and arterial hypertension were found to be significant negative predictors of 6MWD improvement. At baseline, female patients had significant higher left ventricular ejection fraction (49% vs. 42%, p = 0.019) and lower 6MWD (240 m vs. 288 m, p = 0.034) than male patients. CONCLUSION: MitraClip implantation in secondary MR significantly improves functional capacity in high-risk patients even in the short term of four weeks after the procedure. Female gender, diabetes mellitus and arterial hypertension are baseline predictors of a less favourable functional outcome. While further validation in a larger cohort is recommended, these parameters may improve patient selection for MitraClip therapy.


Assuntos
Doença das Coronárias/terapia , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Doença das Coronárias/fisiopatologia , Ecocardiografia , Feminino , Coração/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/fisiopatologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...